helei pushed to master at helei/shuichan_new 2026-09-18 15:35:07 +08:00
7cfb659699 联网选择页第3行去掉上次前缀:模式名从最左显示+秒数紧随,修复长模式名时秒数超宽绕回左边
helei pushed to master at helei/shuichan_new 2026-09-18 15:25:06 +08:00
2fa304d73d 修复联网选择页闪烁:抑制预调度周期刷新+倒计时只更新秒数不重写整行
helei pushed to master at helei/shuichan_new 2026-09-18 15:19:25 +08:00
67fed98891 联网方式改开机按键手动选择:10s倒计时,KEY1=4G/KEY2=WiFi固定/KEY3=配网,超时进EEPROM记忆(首次默认4G);选定后锁定通道原地重试不再自动切换
helei pushed to master at helei/shuichan_new 2026-09-18 14:56:03 +08:00
5bc543237e 移植4G MQTT主动健康检查(每60s查MQTTSTATU,连续3次不在线复位,OTA期间暂停;RSN_MQTT_LOST=18),根治断网假死
helei pushed to master at helei/shuichan_new 2026-09-14 10:57:30 +08:00
721b0f479a WiFi通道指令应答改QoS1+PUBACK端到端确认(重试3次),修复WiFi下继电器动作了但平台响应超时
helei pushed to master at helei/shuichan_new 2026-09-14 10:23:06 +08:00
3cdaba312f 指令应答可靠化:新增NET_publish_response_wait(等OK+重试2次),继电器/扩展板反馈应答换用,修复动作了但平台响应超时
helei pushed to master at helei/shuichan_new 2026-09-13 21:35:13 +08:00
ed955fca03 平台应答文案全部中文化(UTF-8转义):开关/投喂参数无效,重量未就绪,无秤,扩展板离线/忙/无应答等
helei pushed to master at helei/shuichan_new 2026-09-13 21:29:57 +08:00
1cc146dd0e 继电器反馈失败平台应答统一中文:负载断开或继电器损坏(UTF-8转义,板载sw1~4+扩展板sw5~8全部)
helei pushed to master at helei/shuichan_new 2026-09-13 21:18:36 +08:00
105a1dd6ce 上下文: 记录平台文案必须UTF-8字节转义的结论
helei pushed to master at helei/shuichan_new 2026-09-13 21:18:05 +08:00
42326dbe71 回退: sw2中文应答用UTF-8字节转义(直接写中文=GBK字节,平台实测乱码)
helei pushed to master at helei/shuichan_new 2026-09-13 21:14:40 +08:00
b115dcaa65 试验: sw2失败应答改为直接写中文(GBK字节),验证平台是否兼容GBK;乱码则回退UTF-8转义
helei pushed to master at helei/shuichan_new 2026-09-13 21:00:08 +08:00
39232ddcd4 主板sw2反馈失败应答改中文(负载断开或继电器损坏,UTF-8字节),其余路及扩展板保持英文待测试
helei pushed to master at helei/shuichan_new 2026-09-13 20:55:15 +08:00
c83f398415 扩展板反馈失败应答改中文(负载断开或继电器损坏,UTF-8字节转义);仅ext_relay.c这一句,板载英文文案不动待测试
helei pushed to master at helei/shuichan_new 2026-09-13 20:37:10 +08:00
507ab7abda 开机二维码页: OLED显示设备ClientID二维码10s(qrcodegen库,白底暗码+右侧ID文本),未配置不显示;版本号不动
helei pushed to master at helei/shuichan_new 2026-09-08 14:46:25 +08:00
4fb21a4b43 扩展板改按需检测:取消2s轮询,平时零流量;命令三段式(FC03预读+FC05+FC03校验),上电一次性探测保留断电恢复
helei pushed to master at helei/shuichan_new 2026-09-08 13:19:46 +08:00
fa8942aca1 485扩展板轮询帧日志降为debug级(2s例行流量不再刷屏,LOGDEBUG命令可开启查看)
helei pushed to master at helei/shuichan_new 2026-09-08 12:59:21 +08:00
f9c4b3f4cc 扩展板反馈校验加跳变要求(对齐板载语义):命令前快照反馈位,无跳变判失败,防从机反馈卡高误报OK
helei pushed to master at helei/shuichan_new 2026-09-08 12:53:25 +08:00
be448b07af 修复sw5~sw8被旧范围检查拦截(上次改错到relaySet的同名行,已还原)+ext_relay发送前清残留应答标志+故障告警变化才打印
helei pushed to master at helei/shuichan_new 2026-09-04 21:26:26 +08:00
5ee368da7c 扩展板反馈校验对齐板载语义:命令后150ms直接比FC03反馈位(不等1s故障位),失败文案统一为Load unpowered / relay failure !
helei pushed to master at helei/shuichan_new 2026-09-04 21:23:07 +08:00
8f0e137c57 485扩展继电器板状态断电记忆+上线恢复(Relay_State[5]位掩码存EEPROM,离线->上线自动比对纠正);版本号不动保持1.7.1